What’s included:
• High-sensitivity radon detector adapted for ventilation control, with a response time of under 40 minutes
• Can be mounted directly in ventilation ducts, whether exposed to laminar or turbulent flow
• Full access to Radonova web platform via sensor software
• Factory calibrated according to the Swedish Radiation Safety Authority’s standard
• Air pressure, temperature, humidity, and movement sensors
• Automatic connection to LoRaWAN network
• Free LoRaWAN network fee for 3 years
• 30 days’ battery life in the event of power loss
• Measures even without connection, uploading stored data as soon as reconnection to LoRaWAN takes place
A price of 45 € per month is added to the above price if you want to be able to generate reports via Radonova’s My Pages or have access to Radonova’s standard API. This fee only applies per customer and is not dependent on the number of sensors the customer has. If you already use our sensors, this fee will not be charged.
SPIRIT is not dependent on connection via Wi-Fi or Bluetooth. Instead, the public LoRaWAN network is used for communication with Radonova’s servers. The device automatically connects as soon as the network is available.
As network coverage cannot be guaranteed in all locations, we always recommend supplementing with a gateway when purchasing your first SPIRIT device. Via a gateway, you can always reach the LoRaWAN network via a 4G subscription or with a network cable. All your devices can be connected to the gateway within an indoor radius of around 200m.
Order Gateway hereSpecifications
Measuring range | 0 – 100 000 Bq/m³ |
Measurement uncertainty | +-20% at 200 Bq/m³ at two hours integration time |
Sensitivity | 8 cpm at 200 Bq/m³ |
Connection | Wireless (LoRaWAN) |
Temperature range | – 10°C to 50°C |
Humidity area | 0-90% humidity (Non-condensing air) |
Battery life | At least 60 days during measurement |
Power supply | 5V Micro-USB or 10-28V AC/DC |
Dimensions (height, width, depth) | 45 mm, 100 mm, 150 mm |
Weight | 0.35 kg |
Annual service agreement
Preventive maintenance:
- Annual review of the instrument.
- Firmware upgrade, Function tests, Battery test & Filter replacement.
Repairs:
- Prioritisation in case management.
Support and training:
- Free support by phone and email.
Other:
- Service report after completed service / repair.
- Service period for preventive service is normally during May, June or August.
Calibration
Calibration in Radonova chamber:
- Traceability to NIST standard.
- Exact calibration constants are entered in the unit. No correction constants are needed.
- Accuracy + -8% (95% confidence level).
There are no reviews yet.